AUTOMATIC CARDIOTOCOGRAPHY DIAGNOSTIC SYSTEM BASED ON HILBERT TRANSFORM AND ADAPTIVE THRESHOLD TECHNIQUE
- Back
Metadata
Share
Title
AUTOMATIC CARDIOTOCOGRAPHY DIAGNOSTIC SYSTEM BASED ON HILBERT TRANSFORM AND ADAPTIVE THRESHOLD TECHNIQUE
Author
MARQUES, JOÃO ALEXANDRE LOBO | CORTEZ, P. C. | MADEIRO, J. P. D. V. | FONG, S. J. | SCHLINDWEIN, F. S. | ALBUQUERQUE, V. H. C. D.
PUBLISH YEAR
2019
FACULTY / RESEARCH UNIT
Abstract
THE VISUAL ANALYSIS OF CARDIOTOCOGRAPHIC EXAMINATIONS IS A VERY SUBJECTIVE PROCESS. THE ACCURATE DETECTION AND SEGMENTATION OF THE FETAL HEART RATE (FHR) FEATURES AND THEIR CORRELATION WITH THE UTERINE CONTRACTIONS IN TIME ALLOW A BETTER DIAGNOSTIC AND THE POSSIBILITY OF ANTICIPATION OF MANY PROBLEMS RELATED TO FETAL DISTRESS. THIS PAPER PRESENTS A COMPUTERIZED DIAGNOSTIC AID SYSTEM BASED ON DIGITAL SIGNAL PROCESSING TECHNIQUES TO DETECT AND SEGMENT CHANGES IN THE FHR AND THE UTERINE TONE SIGNALS AUTOMATICALLY. AFTER A PRE-PROCESSING PHASE, THE FHR BASELINE DETECTION IS CALCULATED. AN AUXILIARY SIGNAL CALLED DETECTION LINE IS PROPOSED TO SUPPORT THE DETECTION AND SEGMENTATION PROCESSES. THEN, THE HILBERT TRANSFORM IS USED WITH AN ADAPTIVE THRESHOLD FOR IDENTIFYING FIDUCIAL POINTS ON THE FETAL AND MATERNAL SIGNALS. FOR AN ANTEPARTUM (BEFORE LABOR) DATABASE, THE POSITIVE PREDICTIVITY VALUE (PPV) IS 96.80% FOR THE FHR DECELERATIONS, AND 96.18% FOR THE FHR ACCELERATIONS. FOR AN INTRAPARTUM (DURING LABOR) DATABASE, THE PPV FOUND WAS 91.31% FOR THE UTERINE CONTRACTIONS, 94.01% FOR THE FHR DECELERATIONS, AND 100% FOR THE FHR ACCELERATIONS. FOR THE WHOLE SET OF EXAMS, PPV AND SE WERE BOTH 100% FOR THE IDENTIFICATION OF FHR DIP II AND PROLONGED DECELERATIONS.
SUBJECTS
DATABASES,ACCELERATION,ACCURATE FETAL HEART RATE FEATURE DETECTION,ACCURATE FETAL HEART RATE FEATURE SEGMENTATION,ADAPTIVE THRESHOLD TECHNIQUE,ANTEPARTUM DATABASE,AUTOMATIC CARDIOTOCOGRAPHY DIAGNOSTIC SYSTEM,AUXILIARY SIGNAL,BIOMEDICAL MONITORING,CARDIOGRAPHY,CARDIOTOCOGRAPHIC EXAMINATIONS,CARDIOTOCOGRAPHY (CTG),COMPUTERIZED DIAGNOSTIC AID SYSTEM,DIGITAL SIGNAL PROCESSING TECHNIQUES,FETAL DISTRESS,FETAL HEART RATE,FETAL HEART RATE (FHR),FETAL SIGNALS,FHR ACCELERATIONS,FHR BASELINE DETECTION,FHR DECELERATIONS,FHR DIP II,HILBERT TRANSFORM,HILBERT TRANSFORMS,MATERNAL SIGNALS,MEDICAL SIGNAL DETECTION,MEDICAL SIGNAL PROCESSING,MONITORING,OBSTETRICS,PATIENT MONITORING,POSITIVE PREDICTIVITY VALUE,PPV,PREPROCESSING PHASE,SEGMENTATION PROCESSES,TRANSFORMS,UTERINE CONTRACTIONS,UTERINE CONTRACTIONS (UC),UTERINE TONE SIGNALS,VISUAL ANALYSIS
DOCUMENT TYPE
SDG Category
Part of
IEEE ACCESS
DOI
10.1109/ACCESS.2018.2877933